... measurements of the lines in the ultra - violet spectrum of boron from a sample of boric acid obtained from Merck , and gave the wave - lengths of the three lines as 3451 49 , 2497'79 , and 2496.87 . In 1904 A. Hagenbach and H. Konen ...
... measurements of the lines in the ultra - violet spectrum of boron from a sample of boric acid obtained from Merck , and gave the wave - lengths of the three lines as 3451 49 , 2497'79 , and 2496.87 . In 1904 A. Hagenbach and H. Konen ...
Strona 2
... measured by Dr. Weintraub , which at the room temperature ( 27 ° C. ) had a resistance of 5,620,000 ohms , dropped to 5 ohms at a dull red heat . Another noteworthy property of both the melted and agglomerated boron is extreme hardness ...
... measured by Dr. Weintraub , which at the room temperature ( 27 ° C. ) had a resistance of 5,620,000 ohms , dropped to 5 ohms at a dull red heat . Another noteworthy property of both the melted and agglomerated boron is extreme hardness ...
Strona 3
... measured by the thermometer T4 , placed in the glass vessel F. The tem- perature of the water did not vary more than 0.2 ° C. during the measurement , and the slight error caused thereby can be neglected . The aluminium bar was placed ...
... measured by the thermometer T4 , placed in the glass vessel F. The tem- perature of the water did not vary more than 0.2 ° C. during the measurement , and the slight error caused thereby can be neglected . The aluminium bar was placed ...
Strona 4
... measurements . The determinations were made in the other conditions of the bar were constant . The cold water ... measured by a micrometer . The rod was then placed in position in the water - jacket K , which was well lagged with ...
... measurements . The determinations were made in the other conditions of the bar were constant . The cold water ... measured by a micrometer . The rod was then placed in position in the water - jacket K , which was well lagged with ...
Strona 5
... measurements , and 15 cm . in another series . The results were practically identical , as will be seen from the ... measured was about 2.2 mm . , the maximum error of measurement was 0.13 per cent . The error in the temperature ...
... measurements , and 15 cm . in another series . The results were practically identical , as will be seen from the ... measured was about 2.2 mm . , the maximum error of measurement was 0.13 per cent . The error in the temperature ...
Inne wydania - Wyświetl wszystko
Kluczowe wyrazy i wyrażenia
acetic acid action added alcohol alkali alloys aluminium ammonia ammonium amount Analysis APPARATUS atom barium boiling bromine carbon cent cerium Chem CHEMICAL NEWS Office Chemistry chemists chloride chromium CLERKENWELL ROAD colour compounds containing copper creatinine crucible crystallises crystals D.Sc decomposition described determined dilute dioxide dissolved Edition electric electrolytic ester ether ethyl experiments extract Farringdon Street ferric filtered filtrate flask formaldehyde gives gliadin graphite heat hydrate hydrochloric acid hydrogen hydroxide iodide iodine iron Laboratory lead liquid London melting melting-point mercury metal method mgrm mixture molecular molecules Newcastle Street nitric acid nitrogen obtained oxide oxidised oxygen paper phenol Physical platinum potassium precipitate prepared present Price Prof pure quantity radium reaction residue salts samples Sir William Crookes Society sodium sodium hydroxide soil soluble solution substance sulphate sulphide sulphuric acid temperature tion titration tube vanadium volume washed weight Yeast zinc